3 | 
DC Distribution | 
System output voltage | 
Rated output:125VDC | 
| Adjustable range: 90VDC-150VDC continuously adjustable | 
| System output current | 
125V/20A | 
| System load regulation | 
≤±0.5% | 
| System voltage regulation | 
≤±0.5% | 
| System stability precision | 
≤±0.5% | 
| Current sharing capability | 
module current sharing not more than ±5% | 
| Phone balance weight noise | 
≤2mV(@230Vac,full load) | 
| Peak-peak noise voltage | 
≤200mV(0 MHz ~ 20MHz) (@220Vac,half load ~ full load) | 
| system current limit value | 
Power system: 1-22A,Note: can be settable continuously | 
| System voltage drop | 
At full load. the voltage drop of DC distribution within the rack shall below 500 mV | 
| Output distribution | 
Load distribution:3@ 135A  Rail Mount Terminal | 
| Battery distribution | 
Battery distribution:1*@135A Rail mount Terminal | 
|  
 
 
 
 
 
 
 
4 | 
Module And Monitoring Unit | 
Rectifier hot-swap | 
Hot-swap available.not influencing system operation | 
| Rectifier indication | 
with operation.alarm.and fault indicators | 
| Soft start time | 
3s-10s | 
| rectifier fault influence | 
Not influencing the set parameters of rectifier when rectifier at fault | 
| Remote monitoring | 
With remote metering & remote control & remote signaling functions. providing standard RS485&TCP/IP Interface and 6 sets of the dry contact output port & Battery Temp.Sensor | 
|  
Monitoring unit | 
English language in LCD screen of the rectifier, | 
| The parameters can be set through the monitoring unit. with parameter set and power-failure data store functions. Max 1000 Units vents. | 
| Installation method | 
Rectifier module support swappable | 
| Remote control | 
rectifier start and close.battery test. equalize and float charging ,DIN /DO configuration and so on | 
| Alarm functions | 
With AC over voltage/under voltage.DC voltage over/under.module Communication fault and over temperature alarm,Battery remove,Surge and so on | 
| 5 | 
Safety | 
Insulation resistance | 
Testing voltage 500VDC, Insulation Resistance ≥10M  (normal atmospheric pressure, normal temperature, relative humidity <90%, no condensation) | 
|  
Insulation strength | 
Input to output: 3500VDC @1min&leak current ≤10mA | 
| Input to enclosures: 3500VDC @1min&leak current ≤10mA | 
| Output to enclosures:750VDC @1min&leak current ≤10mA | 
| System leak current | 
≤3.5mA(220Vac input) | 
| Grounding performance requirements | 
The system with operating ground and protection ground.with clear mark.the resistance between the enclosures of distribution and all palpable metal components and grounding nut is not more than 0.1Ω | 
| AC lightning protection | 
The equipment AC side can bear simulated lightning impulse Current of waveform 8/20μS and rated amplitude 40kA.(Optional) | 
| EMC | 
In accordance with EN55022 CLASS A,GB9254 CLASS A,FCC PART15 CLASS A,GB17626-1998,IEC 61000-3-2 | 
| 6 | 
Batty | 
Battery low voltage alarm and protection (BLVD) | 
When DC voltage below battery protection threshold value and there is no AC input. the battery protection alarm.lasting for 1 min.battery protection DC connect cut off. | 
| Battery management function | 
With battery management function; with the function of the manual or automatic shift of equalized or float charging status of the battery.current limit charging at equalized state; Temperature compensation for the system output voltage,(equalized and float voltage can be adjusted automatically based on 1~2 00(adjustable)mV/cell/℃.the higher the battery temperature.the lower the float voltage.). |